Huawei Health App Not Working Iphone, Virgo Monthly Horoscope, Articles R

Use the pipe wrench again to tighten up the gas valve. how to fix Rheem water heater chamber sensor failure/9 flashes, Troubleshooting Tankless Water Heater Error Codes, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix], Clean carbon builds up around the electrode. Its because there is no option to repair the gas valve. Includes an integrated NTC temperature sensor. san gabriel valley > If all the wiring is secured and undamaged. Last updated on December 4th, 2022 at 08:36 am. For more information, see our Privacy Statement. Finally, reassemble the burner assembly and turn on the water heater. The heater might stop functioning until you resolve the error. Just follow the below steps to reset it: No, a gas control valve cant be fixed. Just grab a pipe wrench, adjust its jaws, and set the pipe wrench on the gas valve. at the best online prices at eBay! Call 1-855-400-2552 before noon for same-day . A dirty pilot tube is another common cause of a Rheem water heater red light flashing 7 times. The part is required anytime the cag control is damaged or needs replacing. We depend on hot water for various activities ranging from bathing, cleaning, and cooking and for use with other types of equipment. $96.59. The part is required anytime the cag control is damaged or needs . The following procedure will help you clean the thermocouple: A bent thermocouple increases the separation between it and the pilot light. Fortunately, we broke down the way of changing it. Rheem. Hitachi AC Flashing Orange/Red/White/Timer Light Meaning! After the third unsuccessful ignition cycle, the control goes failed ignition lockout and throws an error on display. Flashing red light 1 time in the Rheem water heater signifies the normal operation of the system. You can easily deal with the failed ignition lockout error on your Rheem water heater like a professional if you know the actual reasons with the right solutions. First, unplug the appliance and turn off the gas valve. That means the heater is in tip-top condition, and the complete heating system is functioning quite well. Also, clean the build-up dirt or debris from the power vent. Find many great new & used options and get the best deals for SP20832A - OEM Upgraded Replacement for Rheem Water Heater Natural Gas Valve at the best online prices at eBay! Yes, its hazardous to perform such replacement task that involves gas. Although, the brand has, over time, tried to set up measures to rid and deter most of the problems. Once you get the multimeter, just disconnect the thermopile wire harness from the gas control valve. The core function of the igniter is releasing the intermittent high-voltage sparks through an electrode to ignite the gas. Leaks, Gas, Water, Drain, Sewer, Faucet, Toilet . For screen reader problems with this website, please call 1-800-430 . Now take a look manufacturers chart and compare the resistance at different temperatures with the readings. 72. Replace the damaged ones. #1. Anyway, if anyhow, the combustion gasses fail to move out through the vents, the ignition process interrupts and will lead to the ignition lockout. Replace the cracked hose. If your water heater keeps going into vacation mode, that means the clogged or damaged flame sensor is the root culprit. The gas valve kit ensures the safe and reliable operation of your gas water heater. First, locate the flame sensor from the burner assembly. Also,place the tip of the thermocouple in the proper position. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. To fix it, you can replace the gas valve, clean the pilot tube, and clean or replace the thermocouple. I called a plumber to take a look. Note down the possible reasons relating to venting issues: Most of the time, due to a defective gas valve, you will experience failed ignition lockout even after Rheem water heater maximum ignition attempts. The recall service Rheem offers goes a long way in expressing how the brand is devoted to the satisfaction of its customers. Step 3: Take 400-grit sandpaper and rub the sensor to clean its carbon deposit. There are three fixes to this problem: cleaning the thermocouple, straightening it if bent, or replacing it if broken. $75.00. Rheem Gas Water Heater 14270G-1, 37E73A316 37E73A316P1,SP20296 . $30.00 + $15.02 shipping. Apart from all the above, it leads to gas control valve failure as well. Is as advertised. Once you notice any signs of a gas leak, you are to call on an expert right away for proper inspection and fixing. Cleaning or replacing these parts can help resolve the issue. For instance, Rheem received a statement of control boards overheating their brand and made a recall for the product sold out from January 2014 to April 2016. Here are the steps to help you through: To prevent gas buildup, the thermocouple senses whether or not the pilot flame is lit. The major reasons for causing theRheem water heater to red light flashes about 4 times include: 5 times flashing on the Rheem water heater red light tells you the temperature sensor failure. The gas valve might be clogged by fuel residue, or the damaged gas valve itself is the culprit. With time, the pilot tube can get dirty, leading to a blockage. Here look for broken or burst-out glass vial of TRD. It would help to know that a leaking gas tank is an emergency. There is nothing that needs your attention or troubleshooting. Picture Information. Of course, those problems are also the symptoms of a defective thermocouple. Step 5: Take the new sensor and install it in the burner tube. Then, rotate the pipe wrench counterclockwise to pull out the gas control valve. When I moved into my house about 9 months ago, we had to have a plumber come fix a leaky valve on the hot water heater. All Right Reserved by FIREPLACEHUBS. In Stock. But still, if the issue remains, it is sure the control board gets defective. Look for any signs of wear or corrosion in the wiring. The relief valve controls the amount of water discharged when turned on. 4 FAQs 5 End-Note 650DELTA AP15255A-1 0650501 Rheem water heater OEM gas valve !!L@@K!! Drain The Water Tank 2.3 Step 3. $120.00. Unclog the opening using a piece of wire. First, remove theaccess panel by unscrewing the two screws. Copyright 1995-2023 eBay Inc. All Rights Reserved. Take the heater manufacturers chart and compare the resistance at different temperatures. These pilot lights are small enough that when it's hot, they don't sufficiently heat the air and promote enough air circulation to keep it burning. how to fix Rheem water heater 8 flashes then 1, Most Common Pit Boss Temperature Problems And Their Solutions, 2 times blinking on the Rheem water heater, Rheem water heaters red light blinking 7 times, 9 time blinking on the Rheem water heater red light, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix], Improper thermopile connection to the combination gas control. Step 2: Remove the screws of the burner assembly and slide it out carefully. We are hopeful that this article will help you enough to solve the water heater failed ignition lockout problem easily. Just attach a garden hose to the drain valve which you can find at the bottom of the water heater. Now locate the red button on the thermostat. Keep scrolling! Is There a Recall on Rheem Gas Water Heaters? Turn the shut off valve on the gas line to the on position (parallel with the gas line). The best way around this is to cut off the gas supply and replace the flex tube. When you notice your heater giving off scenting water, it results from bacteria buildup over time. After cleaning, turn on the gas shut-off valve clockwiseand ensure its in the on position. Moreover, Ill cover the fixes for these issues to get your Rheem water heater working again in no time. COPYRIGHT 2023. A faulty Rheem heater gas valve causes inconsistent water temperatures due to inadequate gas flow for proper heating up of the water. Yes, they will send you the replacement-part for free- not the labor cost. Glitches in the power supply are the root reason behind the electric water heater not heating. Measure the water temperature. Now, open the drain valve of your water heater and let the water drain. Some problems common with the Rheem water heater include the following. Rheem SP20166B Water Heater Gas Control Valve Genuine Original Equipment Manufacturer (OEM) Part. The multimeter should display a reading after connecting it to the thermocouple. . Turn the valve off and unplug it from the electrical connection for a minute. Now, set the gas control to pilot and hold down the gas control knob. Now, if you notice that the thermocouple is broken or kinked, it is confirmed that the device is faulty. Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. Once you unhook all the lines from the gas valve, its time to remove the valve from the unit. The pilot button doesnt respond when pushed. Find many great new & used options and get the best deals for RESIDEO / HONEYWELL WT8840A1000 WATER HEATER GAS VALVE CONTROL at the best online prices at eBay! Copyright 1995-2023 eBay Inc. All Rights Reserved. Make sure to clean away any dirt or debris on the tip. Total price: This item: Rheem SP20303D Water Heater Gas Control (Thermostat) NG. For screen reader problems with this website, please call 1-800-430-3376 or text 38698 (standard carrier rates apply to texts) . 2 times blinking on the Rheem water heater is the error indication of thelow thermopile voltage of the water heater. . Commonly referred to as the "T&P" valve. Picture Information. Remove the burner assembly manifold cover to access the combustion chamber. That is the stage our above guide will assist you a lot where you get the problem and solution with a clear description. Get free shipping on qualified Gas Valve Water Heater Accessories products or Buy Online Pick Up in Store today in the Plumbing Department. Also, it is only normal for an overused tank to break down due to wear and tear. 1442 Thermopile Gas Control (Vesta) Valve 1442 Technical Bulletin ABSTRACT: The Vesta Water Heater Control System is a low-power device designed to operate using the millivolt output of a thermopile placed in the pilot flame of the water heater. Read through the below article to get a well-proven troubleshooting guide to resolve failed Ignition Lockout error from the Rheem water heater. Ensure a proper adjustment of the burner assembly after cleaning. In the first step, reset the gas control valve. You need to replace the faulty flame sensor. . However, Rheem promises to offer full inclusion on the defective valve, and the brand is also giving $100 credits to fix organizations to replace the defective parts. We are going through a terrible situation- first the pandemic and second, the war. Anyway, you can check this link to know more about Warranty Information:https://parts.rheem.com/warranty. Also, check the connectors for physical damage. While the brand is rated for its numerous benefits, it has some drawbacks too. When this happens, it shows up as a 'Gas Control Valve Failure'. If so, it shuts off the gas supply. Then, get access to the inducer fan assembly and unclog the stuck debris of the fan and fan motor. COPYRIGHT 2023. Due to the valve failure, it doesn't supply enough fuel to the heater. Save my name, email, and website in this browser for the next time I comment. Ensure a secured placement by tightening the sensors screws. Place the flame sensor back and turn the unit on. Take a brush-attached vacuum cleanerand clean the burner chamber. If the reading is off, replace the dead temperature sensor. Another gas valve problem is that it has too cold water when you need hot water. Inconsistency in temperature is horrible because you might end up getting injured. If it is burnt out or wears out, replaces the whole upper thermostat. It will stop the gas from flowing into your water heater. How To Tell If Rheem Water Heater Gas Valve Is At Problem? A faulty gas valve impedes the pilot light from coming on or causes the pilot light not to stay lit once you let go of the igniter switch. Save my name, email, and website in this browser for the next time I comment. How to replace the gas valve on a Rheem water heater? All you have to do is follow the simple steps below. Adjust it to a higher temperature, but no higher than 120F. Compare . Something went wrong. Your Rheem water heater gives you room to regulate the degree of coldness or hotness you desire your water to be. Over the years, Rheem has constantly produced high-quality water heaters making the brand one of the most sought-after brands. If it gets faulty, no gas will flow to the water heater. Generally, Rheem has excellent prestige for producing credible water heaters, making them a go-to brand for most customers. But when the thermopile voltage becomes low, the pilot light goes, and the gas valve shuts down and turns off the gas supply. Besides, it may cause the water to be too hot or trip the thermal cut-off switch if the gas valve goes bad. Use soapy water to check for leaks. Replace it. Thermopile is an essential element of systems featuring multiple thermocouples. If you dont get the reading, you must replace the thermopile. It is easy to reset a gas valve on your Rheem water heater. Honeywell Resideo Water Heater Gas Valve WV4460E2022. Reassemble the burner assembly and connect all the wires to the control valve. You need to fix the drain and the pressure relief valve. Slowly pull and twist the old thermocouple from its mounting bracket. A faulty gas valve will hinder the pilot light from coming on or remaining lit once you release the igniter control. If it is broken, bent, or damaged, be sure it is in non-working condition. As you look at the water heater flashing 7 times, you may wonder what causes this problem and how to fix it. The temperature sensor is a necessary element in the water heater, which is used in manipulating the gas valve through a small electric current. Then, remove the burner assembly from the unit and observe if there is any clogged dirt and debris. You must ensure that the newly installed flex tube attaches tightly to the control valve before turning on the gas supply for testing. How to reset the Rheem water heater gas valve? We will try to solve the problem as soon as possible. Once cleaning is done, you need to test the igniter electrically using the multi-meter. Hover to . Plug it back again and turn the valve on. Most of the time, the Rheem water heater goes to failed ignition lockout because of malfunctioning of the burner. if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'fireplacehubs_com-large-mobile-banner-1','ezslot_4',113,'0','0'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-large-mobile-banner-1-0');if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'fireplacehubs_com-large-mobile-banner-1','ezslot_5',113,'0','1'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-large-mobile-banner-1-0_1');.large-mobile-banner-1-multi-113{border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:7px!important;margin-left:auto!important;margin-right:auto!important;margin-top:7px!important;max-width:100%!important;min-height:250px;padding:0;text-align:center!important}. While Rheem suggests you call on a professional once you notice a problem with your appliance, it is not out of place to know how to carry out simple fixing procedures. Water By-Pass Control Fault. Its advisable to replace a failed control valve to avoid recurring costs and damage to other parts. 1100 Abernathy Road, Suite 1700 Atlanta, GA 30328, Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the, Inflation Reduction Act and Tax Credits Find out more, Nov. 4, 2016 Tankless Gas Service Bulletin, Tankless Winterization Tech Bulletin 11001, Winterizing Owner Occupied Homes Technical Bulletin 11002, Air-Conditioning, Heating, & Refrigeration Institute. Packaged as promised. - eBay Money Back Guarantee - opens in a new window or tab. It means you need to replace the gas valve once it gets faulty. Add to Cart. (Read This First), Lennox Furnace Error Codes E200/ E201/ E223/ E227/ E229/ E250, Kenmore Dishwasher Error Codes E15, E24, E25, F2E2, F7E1, AE, Cost To Replace Refrigerator Evaporator Fan Motor (LG/ Whirlpool/ GE/ Samsung/ Amana). Discover more about the small businesses partnering with Amazon and Amazons commitment to empowering them. Reset GE Front Load Washer For Error Codes E2/E23/E31/E54! Delivery times may vary, especially during peak periods. Replace the corroded electrode. How Often Can You Flush Your Water Heater? Rheem PROTECH. "This Whirlpool Water heater was purchased through Lowe's on March 29, 2011. Please note that gas storage must be set no lower than 60C and a gas continuous flow booster for a solar system must be set no . Since repairing a failed control valve only serves as a short-term solution, its best to replace it with a new one. The gas reaches the pilot light through the pilot tube, where its ignited to heat the water. If the igniterfails, there will be no spark, and the burner will not light, which leads to the ignition lockout. He stated that a new thermostat/natural gas control was needed. Replace the bad valve. Liebherr Fridge Troubleshooting! You must unclog the pilot tube to fix this issue. [Fixed], 15 Common Rheem Error Codes [Ultimate Guide], Rheem Tankless Water Heater Code 11 (Fixed), Top 5 Navien Tankless Water Heater Problems [Fixed], Whirlpool Duet Dryer No Power To Control Panel (Causes + Solutions). What good is the part if I dont have enough money to pay the serviceman. This triggers the 9-blinking error. But, it will be okay if you have proper knowledge of the possible signs and presentations to enable you to carry out simple fixes when needed. Many factors can cause Rheem heater gas valve problems, including a worn-out gas valve and a general malfunctioning valve. Click to enlarge. However, the appliance will last longer depending on usage and maintenance level. Then, keep depressing the igniter button at the same time. There are some major reasons behind gas valve faults, for instance: Obstructed venting Clogged or damaged burner parts Blocked TRD A faulty thermocouple A defective gas valve Each blinkingmeans different malfunctions of the heater. Loose wiring or connector is one of the most common reasons for ignition lockout in the water. But the exact meaning of the error is mainly determined by the number of blinks. When your tank takes too long to heat, the fault could be a bag gas valve or a faulty burner. Gas coming from the controller travels through the flex tube. Before installing, use Teflon tape on the threaded part of the pipe leading to the hot water. The brand makes high energy efficiency appliances. Temperature & Pressure Relief Valves. Homeguideinfo.com is a participant with Amazon and other Affiliate networks. I will check the warranties carefully before buying this brand again as Im on a fixed income. It will save you hundreds of bucks. Click to . How do you know you need a new hot water heater? If the thermocouple fails, it wont sense the flame, interrupting the ignition system. After completing maximum ignition attempts in the water heater, you may experience an ignition lockout due to a bad thermocouple. The circuit board is powered by this small current and starts heating the water. If the error is still persisting, test the temperature sensor using a multimeter. However, the flame sensor goes bad due to the following 3 major reasons: However, in this stage, we will walk you through how you will deal with the defective flame sensor: if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'fireplacehubs_com-netboard-2','ezslot_21',116,'0','0'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-netboard-2-0');To clean or replace the faulty flame sensor, follow each of the steps described below: Step 1: First, unplug the power connection and shut off the gas shut-off valve. How to tell if the water heater gas valve is bad? Check the main supply tube and pilot supply tube at the gas control valve for gas leaks by using a soap-and-water solution. It is powered from a thermopile heated by the standing pilot flame. How To Reset Rheem Water Heater Gas Valve? As such, when you observe water leaking from your water heater, do a thorough check and be sure of the source of leakage. A defective gas control valve is a leading culprit for this malfunction. If you have any questions about the water heater, leave a comment below. So, its better to test the thermocouple first before swapping the old gas valve. Unfortunately, youll have to replace the device if this is the case. It signals the gas valve whether the valve needs to release or terminate the gas supply. For instance, imagine expecting moderately warm water to pour on you, and then you get a splash of boiling water. Then, pull the burner assembly. To fix the issue, inspect the flex tube for cracks or blockages and clean it if necessary. By continuing to use this website, you agree to our use of cookies. The part is required anytime the cag control is damaged or needs . The gas control valve controls the gas flow to the pilot light and burner. Replace the corroded burner ground wire. A Rheem gas control or valve failure with 7 flashes may be due to a dirty pilot tube, a defective thermocouple, or issues with the flex tube. If you own a storage tank heater, it is ideal for you to flush your heater yearly. Plus, defective ignition control module, bad thermocouple, blocked heater venting, and malfunctioning gas valve are mostly responsible for causing such locked-out ignition failure in a water heater. Iron Maiden Somewhere Back In Time CD New Factory Sealed (#175600215458), Iron Maiden Piece Of Mind CD REMASTERED (1998) (#175565862030), DSSERVO DS3235SSG 35KG Coreless Digital Servo Motor HV 7.4V Steel Gear High 180 (#175568186374). Note: You can also read how to fix Rheem water heater 8 flashes then 1. I am afraid to replace it by myself for injury to my family me or my house I am surprised and very angry I fill cheated with a limited warranty if I had known Id go through this I would have never bought this faulty water heater I am surprised they dont have another recall. And this chapter will let you learn how to replace gas control valve on Rheem water heater. After the purge duration, the blower turns off and lets the pressure switch open. All Right Reserved by FIREPLACEHUBS. Inspect the pressure relief valve, and clean specks of dirt blocked into it. Free shipping for many products! The Rheem PROTECH Gas Control Replacement Kit contains everything that you need to replace the Gas Valve on your Rheem gas water heater. If there is no spark, be sure the electrode is clogged. This error tells you that the water temperature exceeds 180 degrees Fahrenheit and the heater is shutting down. Save my name, email, and website in this browser for the next time I comment. Now lets know the major reasons behind low thermopile voltage from below: Rheem water heater 4 flashes signify high temperature shut down on the water heater. HIGHLY recommended seller! Also, due to the inter-purge duration, the system is being purged. Other major reasons behind burner failure include: In the first step, visually inspect the burnerchamber and check the wiring connection to see any damage or sign of burn. On Thursday, Rheem released a statement to CBS46 confirming that a "small percentage" of residential water heaters produced in 2020-2021 have a problem with a gas valve preventing the pilot light from igniting. Rheem Water Heater Chamber Sensor Failure In many cases, if the thermocouple or the flame sensor fails, the pilot light will not be lit, which affects the complete ignition system. Change the defective gas valve from your Rheem water heater. Select a Model: Gas Control Trade Replacement Valve. if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'fireplacehubs_com-large-mobile-banner-1','ezslot_4',113,'0','0'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-large-mobile-banner-1-0');if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'fireplacehubs_com-large-mobile-banner-1','ezslot_5',113,'0','1'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-large-mobile-banner-1-0_1');.large-mobile-banner-1-multi-113{border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:7px!important;margin-left:auto!important;margin-right:auto!important;margin-top:7px!important;max-width:100%!important;min-height:250px;padding:0;text-align:center!important}. If there is no issue with the thermopile and the pilot light goes out, I bet the gas valve is the culprit. The water heater, with standing pilot lights, features a small device named a thermocouple. Picture 1 of 8. Visually inspect the connectors of the water heater. The table below contains some of the advantages and disadvantages of a Rheem water heater. Picture Information. Then you need to reset the circuits. Pull the damaged igniter from the connection. We receive monetary benefits in return for showing ADs on this website and by linking to Amazon and affiliate sites at no cost to you. Due to damaged wiring connections, the burner doesnt get the electric power that is needed to ignite the heater. Honeywell Resideo OEM Rheem Water Heater Gas Control Valve WV4262E1107 Used. Recently, Rheem admitted that some of her home water heaters manufactured in 2020 and 2021 have impaired gas control valves. Locate the flame sensor and carefully pull it out. Open Monday-Saturday No Overtime Call All Work Guaranteed Family Owned and Operated for 30 Years Lic 794154 10 Years Parts and Labor on Installation 10 Year Warranty Against Latent Defects on We've detected that JavaScript is not enabled in your browser. It is considered one of the big problems in Rheem water heater. There are some major connectors, including an igniter connector, burner tube, and sensor wiring connection to the gas valve. Honeywell GCV valve reset flammable vapor sensor error codeMy Rheem Water heater is giving me 7 flashesReset water heater Just remove the two-wire connectors to the board. The Rheem PROTECH Gas Control Replacement Kit contains everything that you need to replace the Gas Valve on your Rheem gas water heater. $65.00 + $11.45 shipping. Now, open the drain valve and drain the water. While you can try to increase the water temperature to kill the bacteria, cleaning up your heater with a good cleanser like bleach would be best. Rheem Water Heater Gas Valve SP20164 Brand: RHEEM MFG SALES, INC 4 ratings $11370 Rheem/Richmond Water Heater Natural Gas Valve SP8555B RHEEM MFG SALES, INC See more product details Consider this Amazon's Choice product that delivers quickly Amazon's Choice Here are the steps that you have to follow to erase the error: Rheem water heaters red light blinking 7 times indicates the gas control valve failureof the heater. There are some major reasons behind gas valve faults, for instance: Follow the below guide to resolve the 7 blinking from the water heater: If your Rheem water heaters red light is blinking 8 times, it is sure that there is a false pilot signal issue in the heating system. Replace the defective thermopile, and then the 2 blinkings will erase from the heater. Fixing a failed control valve with the help of a technician may not be worth the money, as its only a short-term solution. You can not fix a gas control valve. Then, relight the pilot as instructed in the heater manuals. Rusted or damaged burner ground is the root one among them. For screen reader problems with this website, please call 1-800-430-3376 or text 38698 (standard carrier rates apply to texts) . Inconsistent gas supply to the burner leads to water temperature fluctuations and pilot light challenges. In this case, you must replace it to solve the Rheem water heater gas valve problem. C $240.10 + C $34.46 shipping. Remove the burner access cover and disconnect all the wiring connections to the control valve. Also, suck up all the dirt and debris from the air intake screen with compressed air.